1. The Hydraulic Baler Machine should be used in an environment where the temperature is -10 °C - 50 °C, the relative humidity is not more than 85%, and there is no corrosive gas in the surrounding air and no dust. Like the baler and shrink machine, this hydraulic baler is a three-phase 380V power supply.
2. For the Baler Machine vacuum pump to work normally, the vacuum pump motor is not allowed to reverse. The oil level should be checked frequently. The normal oil level is 1/2-3/4 of the oil window (not over). When there is moisture in the vacuum pump or the color of the oil turns black, the oil should be changed at this time (usually one or two continuous working) Change for the month).
3, the impurity filter should be frequently removed and washed (usually 1-2 months of cleaning, such as packaging debris should shorten the cleaning time).
4. For 2-3 months of continuous operation, the rear cover 30 should be opened to add lubrication to the sliding parts and the switch bumps. The connection activities on the heating rods should be lubricated according to the usage.
5, the pressure relief, filtration, oil mist triplet 24 should be checked frequently, oil mist, oil cup oil (sewing machine oil), filter cup water.